Reviewing and comparing technical configurations applicable to small and medium-scale PHS systems in post-mining and quarry environments
Three main machine-unit concepts were analysed: separate pump and turbine units, three-machine systems, and reversible pump-turbine/PAT configurations. The assessment considered hydraulic performance, investment cost, mechanical complexity, operational flexibility, switching between pumping and generating modes, and suitability for relatively low-head applications. Based on this analysis, a reversible solution using a standardized centrifugal pump operating as a turbine (PAT) was selected as the preferred concept for further development due to its lower CAPEX, availability of industrial components, simplified system architecture and potential for replication. The work also established the main hydraulic and design parameters required for further sizing and optimization of dedicated small PHS units.